EXES-2000EX-200ForEXES-2000 INTERCOM SYSTEMFully Electronic ExchangeINSTALLATION HAND BOOKTOA CorporationKOBE, JAPANEX-200
Use 2-conductor telephone or interphone cables for connection from the exchange to the station.Be sure to use a multi-pair twisted cable such as an in
6. Connection of equipment6-1 Addition of LM unitA basic system using the EX-200 exchange is comprised of 8stations (2 LM units). The LM unit needs
6-2 LM unit wiringFollow the procedures below to connect a station cable to theterminal block CN 2 on the LM unit. The following list showsrelationsh
6-3 Connection of station plug to jack6-4 Mounting option unit(1) Bl unitInsert the Bl unit into its exclusive bay and connect its connector to CN4
6-5 Bl unit connectionAL (Alarm starting input)TM (Timer starting input)ALS (Alarm signal input)IMS (Timer signal input)BS0 (BGM input 1)BS1 (BGM inpu
6-6 RC unit connectionPR1 (Power remote control 1/general purpose control 1)PR2 (Power remote control 2/general purpose control 2)PR3 (Power remote c
6-7 PC unit connectionPG0, PG1-PG11 (parallel data output for pager control)SERIAL OUTPUT (serial data output for pager control)Outputs solely int
NoteDotted lines stand for wiring when two exchanges are connected.6-8 Tl unit connection1-2: Lines for station No.253-4: Lines for station No.265-
6-9 SM unit number settingA maximum of 8 SM units may be used in a system. Establish each unit number by operating SW1switch.1st card2nd card3rd card4
6-10 Connection for speaker stationWhen the speaker station function is employed, cut the corresponding resistor leads as well as jumperwires accordin
This hand book forms part of installation manual for TOA EXES-2000 intercom system. Various functions and externalequipment other than normal speech m
6-11 Connection of power sourceConnect CN1 on the CC unit and CN3 on the FC-210 printed circuit board to AC output of the PU-200or to the external pow
7. Initial set-up and programming (No. 24 programming)Functions the EXES-2000 system has besides basic functions include selectable functions capable
LIST OF FUNCTION AVAILABLE FROM EXES-2000 SYSTEMNote that × × / Y Y (Example. with/without of Item No. 24) shows either ×× or YY can be adopted.1*
The CC unit incorporates a CMOS IC. Particular care is to be taken about its damage static electricity causeswhen you make switch settings.Lithium bat
3. Re-start at Step 1 when mis-dialing occurs.(All other registrations remain valid.)NOTES1. To allow all the stations to have this function,2.
3. Re-start at Step 1 when mis-dialing occurs.(All other registrations remain valid.)NOTES1. To allow all the stations to have this function,2.
3. Re-start at Step 1 when mis-dialing occurs.(All other registrations remain valid.)NOTES1. To allow all the stations to have this function,2. To re
5. STATIONS ALLOWED ACCESS TO EMERGENCY CALL3. Re-start at Step 1 when mis-dialing occurs.(All other registrations remain valid.)1. To allow all the
6. HANDSET STATION REGISTRATIONNOTES1. To allow all the stations to have this function,2. To release at one time the data programmed into all the sta
7. STATIONS ALLOWED ACCESS TO DOOR REMOTE CONTROL AND GENERAL PURPOSE CONTROL3. Re-start at Step 1 when mis-dialing occurs.(All other registrations
Part 1. Outlines of EXES-2000 system and related equipment1. Description and featuresThe Toa EXES-2000 is a fully electronic intercom system, and ha
8. STATIONS ALLOWED ACCESS TO SPEECH MESSAGE3. Re-start at Step 1 when mis-dialing occurs.(All other registrations remain valid.)NOTES1. To allow all
9. DOOR SUBSTATION REGISTRATION3. Re-start at Step 1 when mis-dialing occurs.(All other registrations remain valid.)NOTES1. To allow all the statio
10. SECRETARY TRANSFER3. Programming of Secretary Transfer can be made in a daisy chain method.For their examples, refer to the following sketch.NOTE
11. MASTER/SUB RELATIONSHIP2. Re-start at Step 1 when mis-dialing occurs.(All other registrations remain valid.)NOTES1. To release at one time the da
4. To register stations having consecutive station numbers for this function,5. Re-start at Step 1 when mis-dialing occurs. (All other registration
13. REGISTRATION OF STATION TO REFUSE ZONE 1 PAGING5. Re-start at Step 1 when mis-dialing occurs. (All other registrations remainvalid.)4. To regist
14. REGISTRATION OF STATIONS TO REFUSE ZONE 2 PAGINGNOTES1. All the stations are registered for this function when initial set-up is made.2. To canc
15. REGISTRATION OF STATIONS TO REFUSE ZONE 3 PAGING4. To register stations having consecutive station numbers for this function,5. Re-start at Step
16. REGISTRATION OF STATIONS TO REFUSE ALARM AND TIME ANNUNCIATIONNOTES1. All the stations are registered for this function when initial set-up is ma
8. Performance TestAfter finishing station No.24 programming, perform operation tests from each station. Write downthe test results in "Initial C
Central control unit CC-20:This unit is comprised of a CPU that processes the exchange procedures, a speech link consisting of avoice switch circuit a
Trouble-shooting at the time of installation(1) Cannot dialAll stations?No (Specified stations)YesSwitch settings for SW1 andSW
Wrong wiring. Wrong DIP switch settings. Error in No. 24 programming.Selectable functions cannot be operated.Error in No. 24 programming.(5) Other tro
9. FUNCTION TABLE FOR STATIONSFunction Table for Stations20212223242526272829303132333435363738394041424344454647484950FunctionHardwired Station No.Na
10. STATION DATA TABLEStation Data Table20212223242526272829303132333435363738394041424344454647484950ItemStation No.NameType of stationsCheck if conv
Printed in Japan133-06-135-6C
Part 2. Installation of EXES-2000 systemInstalling and adjusting proceduresFollow the procedures below to install and adjust the EXES-2000 system:Ob
4-2 Installation of the exchangeFollow the procedures below to install the EX-200 exchange:Unscrew 4 side screws toremove the top case.Fix the exchang
Note(1) Since the YR-820 and YR-821 cables are to be usedfor connecting the FC-210 to the EX-200 exchange,there is a limit to spacing between the tw
Follow the procedures below to install the PU-200:Remove 4 case fixing screws and fit the attachedwall mounting kit.Fix on the wall. In the event tha
4-5 Installation of StationsTo install stations, make connections by using station jack model YC-601 (Wall-mounted type) or YC-603(Flush-mounted type)